How to Repair Commercial Carpet Cleaning Machines
There are several models of commercial carpet cleaning machines available on the market today. Just like with all other mechanical devices of this type, at some point they will stop functioning properly and need repairs. In order to save you both money and time, here a few simple tips that you should try first to avoid costly repair shop fees.
- First, inspect the power cord for any damage. If you do find damage to the power cord do not attempt to power the machine on. If not, ensure that the on/off switch is placed in the on position. Verify that the power cord is plugged securely in the electrical outlet. If so, try several other outlets to ensure that you are not plugging the machine into a faulty outlet.
- Inspect the belts of the carpet cleaner for any visible damage. A belt that is damaged will cause the brushes to stop rotating or cause the spray component to not operate correctly. To fix this type of damage you first need to disconnect the machine from its power source. Utilize the user guide to establish the exact location of each belt. Inspect the belts again for damage and visit the manufactures website or your local home improvement store to purchase a replacement.
- If your machine is suffering from low or no suction first disconnect the machine from its power source. Inspect the nozzle and all other attachments to ensure that they have been attached correctly. Check the gasket that is located near the bottom of the tank to ensure that is has also been positioned correctly. If not, you can easily move it back into its proper place. However, if the gasket is missing or damaged, you'll need to purchase a replacement. Double check that the lid of the tank is correctly positioned and if not, remove it and reinstall it correctly.
- If the commercial carpet cleaning machine is not properly outputting the cleaning solution it will also need repairs. First, ensure that there is a tank full of clean hot water. Next, ensure that the cleaning solution is filled with the suggested manufacture's solution. Third, if the dispensing button on the attached pump is stuck, disconnect the machine from the power source for at least one minute while holding down the trigger. Lastly, check the filter for any clogs or other debris.