How to Wire Alarm Zone Resistors
Resistors utilized to terminate protective loops or zones are known as end of line resistors. End of line resistors allow the control panel to monitor the wiring for open or short circuits. The response of the control panel to an open or short circuit depends on proper wiring of the alarm zone resistor. The following procedure will assure the panel differentiates between an open or short circuit and an actual alarm.
Items Needed:
- Alarm
- End of line resistor
- Pliers
- Screwdriver
- Purchase the correct size end of line resistors for the alarm system, generally 6,800-Ohm, 1/4-watt resistors.
- Open the circuit breaker box and switch off the voltage to the alarm control panel.
- Expect an alarm to sound, when switching the voltage off.
- Disconnect the battery backup terminals, labeled B+ and B-, from the panel terminals.
- Examine the control panel to find the alarm zone terminal strip labeled ZN-1, ZN-2, ZN-3 and consecutively numbered for each alarm zone.
- Determine the unused zones by locating zones that do not have a wire attached.
- Place an end of line resistor across each unused zone.
- Utilize the pliers to form loops in the end of the resistor’s leads.
- Arrange the resistor lead loops under the terminal screws and tighten by turning with a screwdriver. The loops should be placed in a clockwise direction to the right.
- Determine the station connected to each zone.
- Position an end of line resistor across the terminal on the station of the last zone utilized to assure proper monitoring. Otherwise, the alarm could become nonfunctional for a particular zone without warning the control panel.
- Reattach the battery backup leads.
- Switch the line voltage circuit breaker to the on position.
- Position the control panel covers in place.
- Push the reset button to rearm the alarm system. Some systems may have specific instruction for resetting the alarm.