How to Wire a Commercial Freezer

No one enjoys the malfunction and down time of their equipment. A commercial freezer going on the fritz can cost dozens of man hours. It is important to remember when attempting repairs that commercial freezers vary between manufacturers. Make sure you have your owner’s manual available and on hand to consult during your wiring or repair projects.


  1. Locate your primary circuit breaker. It should be prominently displayed, but each building varies by architectural style. Be sure to consult your household and or business blueprints to locate your primary breaker box.

  2. Turn off your power. All circuits should be appropriately labeled to enable you to locate the switches to temporarily turn off your power for your re-wiring tasks. Remember to try the light switches within the main gathering rooms and appliances to ensure that the power is indeed truly off.

  3. Install a proper 240-volt (commonly referred to as a dual pole circuit) circuit breaker. Remove your cover protecting the panel containing your primary circuits and plug in your 240-volt circuit breaker into an empty slot. Installing the proper circuit breaker will insure the correct flow of electrical power getting to your freezer.

  4. Remove the outer plate of your double pole three ‘female’ receptacle and unscrew it from the box. You will want to mount this receptacle close to your freezer and draw its double pole, three wires cabling through the small opening available on the top of the electrical box and into the box itself for roughly 8 inches.

  5.  Strip the cable. Grab your splicer and remove roughly 4 to six inches of the outer cover of the cable tip. You will want to strip an additional ½ inch to an inch of insulation from the tip of the three inner wires contained within.

  6. Loosen all screws, including the green terminal screw at the very base of the receptacle and mark off a band of color on the surface of the white wire using a highlighter pen to mark it as “live.”

  7. Attach each of the three wires to their corresponding screw on the receptacle in a clockwise manner. The white wire should go to a brass terminal screw, as should the black, as they are both active and hot. The green wire placed upon the green terminal screw, as that is the ground.

  8. Tighten down all your screws connecting the wires to their respective terminal screws.

  9. Run your cable to the electrical panel and strip away a bit of the cables sheathing so that you can spread the wires. Put the black and white wires on to the terminal end of your double pole breaker and your green wire on the grounding bar.

  10. Insert your green or ground wire well into the slot beneath the terminal screw on the end of the circuit breaker. Your black wire goes into the slot next to the ground.

  11. Tighten your screws to secure your connections.