Flashing Light Spa Side Error Codes
Feb 13, 2011
Aqua-Docs - 717-389-6723
Flashing Light Spa Side Error Codes
| 1 flash - 3 second gap | High Limit fault |
| 2 flashes - 3 second gap | Pressure/Flow switch short circuit |
| 3 flashes - 3 second gap | Pressure/Flow switch open circuit |
| 4 flashes - 3 second gap | Open circuit Sensor(s) |
| Flash - 1 second on, 1 second off | Same as OH |
| Flash - briefly OFF once per second | Same as Sn1 or Sn3 |
| Flash - briefly ON once per second | Same as FLC |
| Blinking Power Indicator Light - Hydromate | High Limit tripped or, sensor fault |
| 1 flash per second - onga 4352, 53, 95, etc |
Pressure switch open circuit - could also be motor, or motor thermal overload |
| 3 flashes per second - onga 4352, 53, 95, etc |
Electronic fault - sensor (most common cause) or PCB |
| Green flashes - Spaquip Pulsar/2095 series | Water sensor fault - lack of water |
| Red/Green alternate flashes | Temperature sensor fault, open circuit, or high limit tripped - push Reset Rod |