Aqua-Docs

3 reviews
Claimed   •  Computer Repair , Pools, Spas, & Saunas
717-389-6723
25 Mazzotta Road Stevens, PA 17578 40.247033 -76.156432
verified

Jacuzzi Whirlpool Spa Side Error Codes

Feb 13, 2011
AQUA-DOCS - Your hot-tub and Pool Service Professionals
  • OH = Overheat Protection (Heater is deactivated, pumps low speed is activated).
  • COOL = Spa water is more than 20° F cooler than the temperature set point.
  • FLO = Flow Switch (heater is deactivated. Pump may also be deactivated).
  • Hold = Panel sensors have been pressed too many times in a short period of time.
  • HOT = Circuit Board temperature has exceeded acceptable limit.
  • ICE = Freeze protection.  No action is necessary.
  • ICE2 =  Freeze protection.  No action is necessary.
  • PnL = Communication between the panel and circuit board is faulty.
  • ---- = "Watchdog" (spa is deactivated) A problem has been detected.
  • Sn1 = Open sensor (heater is deactivated) or  Shorted sensor (spa is deactivated).
  • Sn3 = Open or shorted sensor ( heater disabled).
  • FLO2 = Closed or shorted flow switch on system startup
www.aqua-docs.com - 717-389-6723