Aqua-Docs Blog
Aqua-Docs - 717-389-6723 Water Chemistry The APSP publishes recommendations for water balance that apply equally to pools equipped with salt chlorine generators. Following these guidelines will help keep pools clean and clear while protecting the equipment and the pool finish. In addition, stressing these guidelines with customers will dispel any misconceptions they may have about salt chlorine generators being a replacement for routine chemical maintenance. Free chlorine:Maintain at 2.0-3.0 ...
READ MORE
Posted March 04, 2011 at 05:40 AM
Aqua-Docs - 717-389-6723 Water Chemistry Keeping your water chemistry balanced is imperative to keeping a swimming pool clean, clear, and in good working order. The swimming pool's structure and filter system can be adversely affected if the water is not kept in balance. The following are the levels that we recommend for proper pool water balance: Free Available Chlorine 2 - 3 p.p.m. Combined Chlorine 0 p.p.m. Bromine 3 - 5 p.p.m. pH 7.4 Total Alkalinity 80 - 120 p.p.m. Calcium Hardness...
READ MORE
Posted February 25, 2011 at 09:39 AM
Aqua-Docs - 717-389-6723 Flashing Light Spa Side Error Codes 1 flash - 3 second gap High Limit fault 2 flashes - 3 second gap Pressure/Flow switch short circuit 3 flashes - 3 second gap Pressure/Flow switch open circuit 4 flashes - 3 second gap Open circuit Sensor(s) Flash - 1 second on, 1 second off Same as OH Flash - briefly OFF once per second Same as Sn1 or Sn3 Flash - briefly ON once per second Same as FLC Blinking Power Indicator Light - Hydromate High Limit tripped or, sensor fault 1 f...
READ MORE
Posted February 13, 2011 at 11:51 AM
AQUA-DOCS - Your hot-tub and Pool Service Professionals OH= Overheat 108° F, spa is deactivated. Do not enter the water. FL= Flow. Pressure switch is not working. SN= Non functional high temperature sensor. Heater is deactivated. F2= 4 hours daily filtration F4= 8 hours daily filtration F6= 12 hours daily filtration FC= continuous filtration www.aqua-docs.com - 717-389-6723
READ MORE
Posted February 13, 2011 at 10:56 AM
AQUA-DOCS - Your hot-tub and Pool Service Professionals OH= Overheat Protection (Heater is deactivated, pumps low speed is activated). COOL= Spa water is more than 20° F cooler than the temperature set point. FLO= Flow Switch (heater is deactivated. Pump may also be deactivated). Hold= Panel sensors have been pressed too many times in a short period of time. HOT= Circuit Board temperature has exceeded acceptable limit. ICE= Freeze protection. No action is necessary. ICE2= Freeze ...
READ MORE
Posted February 13, 2011 at 10:53 AM
AQUA-DOCS - Your hot-tub and Pool Service Professionals C= Celsius CL= Current Time of Day ECdu= Economy Mode Duration Econ= Economy Mode Turn On F= Fahrenheit Fldu= Filter Cycle Duration Flon= Filter Cycle Turn On FLC= Pressure Switch Alarm FLO= Pressure Switch Alarm FrEE= Freeze Protection Alarm HL= High Temperature Alarm Loc= Panel / Keypad Locked PrH= Temperature Sensors Alarm Prr= Temperature Sensors Alarm Tu= Temperature Set Celsius Tu= Temperature Set Fahrenheit www.aqua-docs.com - 717...
READ MORE
Posted February 13, 2011 at 10:50 AM
AQUA-DOCS - Your hot-tub and Pool Service Professionals err 1 (H20): Prime Failed err 3: Stuck Button err 4: No Water Sensor err 5: Overtemperature err 6: Thermal Cut Out Tripped err 7: Stuck Relay err 8: No Temperature Data 01: Stuck Button 02: No Controller Data 03: Temperature Sensor 04: Water Sensor 05: Spa Over Temperature 06: Heater Thermal Cut Out 07: Stuck Heater Relay 09: Water Prime Failed www.aqua-docs.com - 717-389-6723
READ MORE
Posted February 13, 2011 at 10:48 AM
AQUA-DOCS - Your hot-tub and Pool Service Professionals PS: Flow or pressure switch failure SH: Shorted sensor OP: Open Sensor Degrees LO: Temp below 60 degrees - freeze HL: Temp above 118 degrees OH: Spa temp exceeds acceptable limits FLO: Flow problem ICE: Freeze condition detected SN1: Hi-limit sensor failure SN2: Temp sensor failure www.aqua-docs.com - 717-389-6723
READ MORE
Posted February 13, 2011 at 10:41 AM
AQUA-DOCS - Your hot-tub and Pool Service Professionals FLO: Pressure switch failure, switch open FLC: Pressure switch failure, switch closed Prr: Temp sensor failure Prh: Hi-limit sensor failure HL: Sensor measuring 119 degrees FrE: Possible freeze condition detected www.aqua-docs.com - 717-389-6723
READ MORE
Posted February 04, 2011 at 08:12 PM
AQUA-DOCS - Your hot-tub and Pool Service Professionals pd= Power supply, unit running on battery backup OH= Sensors reading 112-118° F. OHH= Overheat. Spa has shut down. One sensor has detected 118º F at heater. OHS= Overheat. Spa has shut down. One sensor has detected 110º F. Flo= Improper flow or pressure switch malfunction Cool= Water temp 20° below set point ICE= Potential freeze condition has been detected Sn1= Hi-limit sensor malfunction Sn3= Temp sensor malfunction SnA= Spa is shut do...
READ MORE
Posted February 04, 2011 at 08:11 PM